What is a battery safety management system?
safety management
The battery safety management system primarily ensures the safe and efficient operation of the battery pack, preventing it from catching fire due to high temperatures or failing due to low temperatures. Because the battery pack is a high-voltage device, a high-voltage insulation protection system is essential to ensure the safety of vehicle occupants and pedestrians. The battery safety management system must be able to maximize the performance of both the battery and the vehicle while ensuring safe vehicle operation. The development of battery safety management systems is of great significance for ensuring the safety of life and property and promoting the development of electric vehicles.
High-voltage insulation testing system
The energy storage devices in electric vehicles, such as power battery packs, fuel cells, or supercapacitors, operate at voltages far exceeding the safe voltage range for the human body; some electric buses even have battery packs operating at 600V. The insulation performance of the insulating materials in the vehicle gradually deteriorates during use due to wear and tear, and increased humidity also reduces the insulation performance between the high-voltage power battery and the chassis. When the insulation layer of the battery's positive and negative terminals is worn through and comes into contact with the chassis, a leakage current loop is created, affecting the operation of the motor controller, other low-voltage electrical appliances, and even endangering passenger safety. When the insulation between multiple points of the battery pack circuit and the chassis ages, self-discharge and energy accumulation occur, potentially leading to a fire in severe cases. To ensure the safe operation of the vehicle, an insulation performance detection device must be installed to monitor the insulation resistance between the high-voltage system and the chassis in real time.
Commonly used insulation testing methods include:
1. Direct Leakage Measurement Method
In DC systems, this is the simplest and most practical method. Set a multimeter to the current range and connect it in series between the positive terminal of the battery pack and the device casing (or ground). This will detect the leakage current between the negative terminal of the battery pack and the casing. Similarly, it can be connected in series between the negative terminal and the casing to detect the leakage current between the positive terminal and the casing. This method is simple and easy to implement, and is commonly used in on-site fault detection and routine vehicle inspections.
2. Current Sensing Method
A Hall effect current sensor is a common method for detecting leakage in high-voltage DC systems. The positive and negative power buses of the battery system are passed together in the same direction through the current sensor. When there is no leakage current, the current flowing from the positive terminal is equal to the current returning to the negative terminal. Therefore, the current passing through the current sensor is zero, and the current sensor output voltage is zero. When leakage occurs, the current sensor output voltage is not zero. The sign of this voltage can be used to further determine whether the leakage current originates from the positive or negative terminal of the power supply. However, this testing method requires the battery pack under test to be operational, with current flowing in and out. It cannot evaluate the battery system's insulation performance to ground under no-load conditions.
3. Insulation Resistance Meter Measurement Method
This method uses an insulation resistance meter to measure the resistance value of the insulation. An insulation resistance meter, commonly known as a megohmmeter, is often powered by a hand-cranked generator, hence also called a megohmmeter. Its scale is based on insulation resistance and is a commonly used measuring instrument in electrical engineering. Its working principle is shown in Figure 8-29.
The instrument works by exciting the device or network under test with a voltage, then measuring the current generated by the excitation, and using Ohm's law to measure the resistance. The insulation resistance meter mainly consists of two parts: a hand-cranked generator and a magnetoelectric ratio meter. By cranking the handle, the hand-cranked generator generates AC high voltage, which is rectified by a diode to provide DC high voltage for measurement. The magnetoelectric ratio meter then measures the ratio of the current in the voltage coil and the current coil, and the pointer indicator indicates the resistance scale.
The above three methods all employ proprietary equipment for leakage current and insulation resistance testing, which presents certain difficulties for integration into battery management systems. Circuit measurement methods are more commonly used in battery management systems. The principle of commonly used DC voltage insulation measurement is shown in Figure 8-30.


In this block diagram, R₁, R₂, R₃, and R₄ are high-resistance resistors (e.g., 500kΩ or higher), ensuring that the insulation level does not artificially decrease during measurement. Rₙ and Rₚ are the insulation resistances of the positive and negative terminals of the power battery pack to the vehicle body, respectively. R' and R" are voltage divider resistors with small resistances (e.g., around 2000Ω), allowing the A-D conversion chip to obtain mV-level analog signals across them.
When switch S is in the off state, the voltage values across Rₙ and Rₚ can be obtained through the measuring chip, leading to the following equation:

In the formula, V₁ and V₂ represent the voltages to ground of the positive and negative busbars when switch S is open.
Similarly, when switch S is closed, another equation can be obtained:

In the formula, V'₁ and V'₂ represent the positive and negative busbar voltages to ground when S is closed.
Since the resistance values of the series resistors R₁, R₂, R₃, R₄, R, and R' are known, the system of equations (8-5) and (8-6) can be used to solve for R₊ and R₋.
Other insulation resistance measurement methods used in battery management systems include the balanced bridge method, the high-frequency signal injection method, and the auxiliary power supply method. As the voltage of power batteries increases and their applications become more widespread, the insulation safety of electric vehicles becomes increasingly important, and researchers are continuously designing and validating various insulation monitoring methods.
Peak Power
SOP (State of Power) is the maximum power a battery can release or absorb within a predetermined time interval. Peak power is used to evaluate the charging and discharging limits of a power battery under different states of charge, playing a crucial role in optimizing the matching between the power battery pack and vehicle power performance, as well as maximizing the regenerative braking function of the electric motor. It also has significant theoretical and practical value for the rational use of batteries, avoiding overcharging or over-discharging, improving battery safety, and extending battery life. However, battery peak power is subject to numerous safety limitations; only peak power within these safety limits has practical significance. This section discusses some battery parameters that limit peak power and explores the relationship between battery safety and peak power.
1. Temperature-Based Constraints
The conductivity of the electrolyte and the activity of the anode and cathode materials change with temperature, thus affecting the upper limit of the battery's charge and discharge power. The reaction rate of the electrodes decreases as temperature decreases. Temperature also affects the transport rates of ions and electrons in the electrolyte. These rates increase with increasing temperature and vice versa. Furthermore, if the temperature is too high, exceeding the specified temperature limit, the chemical balance within the battery will be disrupted, causing battery safety issues.
As shown in Figure 8-31, the peak power of the battery changes with temperature, exhibiting a clearly non-linear curve. Peak power decreases as temperature decreases, changing slowly at low temperatures. Peak power increases as temperature increases, but excessively high temperatures make heat dissipation difficult, negatively impacting battery safety and lifespan.
2. State of Charge (SOC)-Based Constraints
The SOC constraint on SOP (Start of Operation) is designed to prevent overcharging and over-discharging of the power battery during operation, ensuring battery safety. When studying the relationship between peak power and SOC, the influence of factors such as temperature and charge/discharge rate on SOC must also be considered to improve the accuracy of SOC measurement. As shown in Figure 8-32, with the increase of State of Charge (SOC), the discharge power increases while the charging power decreases. For example, within the same SOC range, when the SOC increases from 10% to 90%, the peak discharge power increases from 222W to 693W, while the peak charging power decreases from 675W to 300W. Studying the peak power under different SOC conditions can estimate the battery's charge and discharge capabilities, providing data and technical support for its use in electric vehicles.
3. Constraints Based on Ohmic Resistance
As shown in Figure 8-33, the peak power of a battery is approximately inversely proportional to its ohmic internal resistance. The smaller the ohmic internal resistance, the greater and faster the peak power output; conversely, the greater the ohmic internal resistance, the smaller and slower the peak power output.


The battery's temperature, state of charge (SOC), and internal resistance are all closely related to its safety status. Therefore, the battery's state of operation (SOP) must meet the constraints imposed by these three factors to ensure safe operation and extend its lifespan.