What are the basic testing principles and methods for power batteries?
Basic Principles and Methods of Power Battery Testing
The basic electrochemical properties of chemical power sources include capacity, voltage, internal resistance, self-discharge, storage performance, high and low temperature performance, etc. As a typical secondary chemical power source, power batteries also include charge and discharge performance, cycle performance, internal pressure, etc. Therefore, the main performance testing contents for a single power battery cell include: charge and discharge performance testing, discharge performance testing, discharge capacity and rate performance testing, high and low temperature performance testing, energy and specific energy testing, power and specific power testing, storage performance and self-discharge testing, life testing, internal resistance testing, internal pressure testing, and safety testing, etc.
From the perspective of actual vehicle application, a series of tests suitable for vehicle use are carried out with the power battery pack applied to electric vehicles as the test object, such as: static capacity detection, dynamic capacity detection, quiescent test, starting power test, rapid charging capability test, cycle life test, safety test, battery vibration test, peak power detection, partial discharge detection, maximum gradient power test, thermal performance test, etc.


(1) Static Capacity Detection The main purpose of this test is to determine that the power battery pack has sufficient charge and energy when the vehicle is in actual use, and can work normally under various predetermined discharge rates and temperatures. The main test method is slow discharge testing under constant temperature conditions, and the discharge is terminated when the voltage of the power battery pack drops to a set value or the consistency of the single cells within the power battery pack (voltage difference) reaches a set value.
(2) Dynamic Capacity Detection During the operation of an electric vehicle, the operating temperature and discharge rate of the power battery are dynamic. This test mainly detects the capability of the power battery pack under dynamic discharge conditions, which is mainly reflected in the energy and capacity at different temperatures and discharge rates. The main test method is to perform discharge performance testing of the power battery pack using a predetermined current profile or a current profile actually collected from the vehicle's application. The termination condition of the test is adjusted according to the test conditions and the characteristics of the power battery, but basically follows the standard of the voltage dropping to a certain value. This method can more directly and accurately reflect the actual application needs of electric vehicles.
(3) Quiescent Test The purpose of this test is to detect the capacity loss of the power battery pack when it is not in use for a period of time, which is used to simulate the situation where the electric vehicle is not driven for a period of time and the battery is left open-circuit. The quiescent test is also known as the self-discharge and storage performance test, which refers to the ability of the battery to maintain its stored charge under certain environmental conditions when it is in an open-circuit state.
(4) Starting Power Test Since the starting power of a car is relatively large, in order to adapt to the car's starting under different temperature conditions, starting power tests are conducted on the power battery pack at low temperature ($−18\text{°C}$) and high temperature ($50\text{°C}$). This test, in addition tobeing measured at room temperature, is generally also set with an SOC value in order to determine the discharge capability of the battery at different states of charge. Common tests are power tests conducted at $90\%$, $50\%$, and $20\%$ SOC.
(5) Rapid Charging Capability Test The purpose of this test is to test the rapid charging capability of the battery by performing high-rate charging tests on the power battery pack, and to examine its efficiency, heat generation, and impact on other properties. For rapid charging, the USABC standard aims for the battery SOC to recover from $40\%$ to $80\%$ within $15\text{min}$. Currently, the standard set by Japan's CHAdeMO association requires that charging the electric vehicle power battery pack for about $10\text{min}$ can guarantee the vehicle travels $50\text{km}$; charging for more than $30\text{min}$ can guarantee the vehicle travels $100\text{km}$.
(6) Cycle Life Test The cycle life of the battery directly affects the economic viability of battery use. When the actual capacity of the battery is lower than $80\%$ of the initial capacity or rated capacity, the power battery is considered to have reached the end of its life. The main method used in this test is to perform charge and discharge cycles under certain conditions, using the number of cycles as the index of its life. Since the test period for power battery life is relatively long, the test generally lasts for several months or even a year. Therefore, in practical operation, methods of determining the number of test cycles, measuring the capacity degradation, and then performing linear extrapolation based on this data are often used for testing. In the field of research, in order to shorten the power battery life test time, studies are also being conducted on accelerating battery aging by increasing the test temperature and charge/discharge rates to test the life of power batteries and power battery packs.
(7) Safety Test Battery safety performance refers to the assessment of potential harm to people and equipment that may be caused by the storage and use of storage batteries. Especially when the battery is abused, specific energy input causes the internal constituent materials of the battery to undergo physical or chemical reactions that generate a large amount of heat. If the heat cannot be dissipated in time, it may lead to battery thermal runaway. Thermal runaway can cause the battery to bulge, generate flammable gas, rupture, crack, and be accompanied by fire, causing safety accidents. Among many chemical power sources, the safety of lithium-ion batteries is particularly important. Common safety testing items for power batteries are shown in Table 6-1.

Table 6-1 Common Safety Testing Items for Power Batteries
| Category | Main Test Methods |
| Electrical Performance Test | Overcharge, over-discharge, external short circuit, hot discharge, etc. |
| Mechanical Test | Free fall, impact, extrusion, vibration, extrusion, etc. |
| Thermal Test | Burning, thermal imaging, thermal shock, temperature fluctuation, etc. |
| Environmental Test | Vacuum simulation, immersion, humidity, etc. |
(8) Battery Vibration Test The purpose of this test is to detect the impact of frequent vibrations and shocks caused by roads on the performance and life of power batteries and power battery packs. The battery vibration test mainly examines the vibration durability of the power battery (pack) and uses this as a basis to guide the structural design improvement of the power battery (pack). There are two types of vibration in vibration testing: sinusoidal vibration or random vibration. Since power battery packs are mainly used in vehicles, random vibration is generally adopted to better simulate the actual operating conditions of the battery.
The above are just some general requirements for testing power batteries (packs). The specific parameters and requirements of the test will vary depending on the type of power battery. Table 6-2 shows the safety performance requirements and test methods for lithium-ion battery packs and systems used in electric vehicles.
Table 6-2 Safety Performance Requirements and Test Methods for Lithium-ion Battery Packs and Systems in Electric Vehicles
| Item | Category | Test Method | Safety Requirements |
| Common Safety Testing (Table 6-1) | Electrical Performance Test | Overcharge, over-discharge, external short circuit, hot discharge, etc. | N/A |
| Mechanical Test | Free fall, impact, extrusion, vibration, extrusion, etc. | N/A | |
| Thermal Test | Burning, thermal imaging, thermal shock, temperature fluctuation, etc. | N/A | |
| Environmental Test | Vacuum simulation, immersion, humidity, etc. | N/A | |
| EV Li-ion Battery Safety (Table 6-2) | Vibration | 1. Test Object: Battery Pack or System. 1. Refer to vehicle mounting requirements and GB/T 2423.43-2008, install on vibration table. Test in 3 directions ($Y \to X \to Z$). Procedure refers to GB/T 2423.56-2018. 2. For lower-body installations, test parameters according to 7.1.1.2 in GB/T 31467.3-2015. 3. Test time is $2\text{h}$ per direction (can be reduced to $0.5\text{h}$). $2\text{h}$ observation allowed during or after $30\text{min}$. 4. Monitor minimum monitoring unit status (voltage, resistance, temp). 5. Observe $2\text{h}$ during test. 6. For electronic devices: i. Front-mounted: Test per 7.1.1.2.1 in GB/T 31467.3-2015. Other locations: Test per GB/T 28046.3-2011. $2\text{h}$ in different $Z$-axis directions. Lateral objects: excitation mode conducted. ii. Operate in $3.2$ mode per GB/T 28046.1-2011. | Battery pack or system must: Have no voltage decay in minimum monitoring unit ($< 0.5\text{V}$), remain intact, structure sound, no leakage, no rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ within $30\text{min}$ after test. Electronic devices: Reliable connection, structure sound, no disconnection. Post-test parameters meet Table 1 in GB/T 31467.3-2015. |
| Mechanical Shock | 1. Test Object: Battery Pack or System. 2. Refer to 7.2 Shock $25\text{g}\text{-}15\text{ms}$ half-sine pulse in GB/T 31467.3-2015, $3$ shocks in $Y$-axis direction, observe $2\text{h}$. | No leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$. | |
| Drop | 1. Test Object: Battery Pack or System. 2. Drop from $1\text{m}$ onto hard ground in the most likely drop direction (otherwise most stable possible drop direction, $X$-axis test), observe $2\text{h}$. | No discharge current lock, voltage surge or leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Rollover | 1. Test Object: Battery Pack or System. 2. Refer to 7.3.2 in GB/T 31467.3-2015: $90\text{°}$ tilt for $6\text{h}$, then $90\text{°}$ increments, hold $1\text{h}$ each, $360\text{°}$ rotation stopped. Observe $2\text{h}$. 3. Rotate $360\text{°}$ around $X$-axis at $6\text{°}/\text{s}$, then $90\text{°}$ increments, hold $1\text{h}$ each, $360\text{°}$ rotation stopped. Observe $2\text{h}$. 4. Rotate $360\text{°}$ around $Y$-axis at $6\text{°}/\text{s}$, then $90\text{°}$ increments, hold $1\text{h}$ each, $360\text{°}$ rotation stopped. Observe $2\text{h}$. | No leakage, outer casing rupture, fire, or explosion, maintain reliable connection. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Maximum Gradient | 1. Test Object: Battery Pack or System. 2. Mounted horizontally on a trolley. Repeat the pulse specified in Fig 3 of Table 7 in SAE J2380 or GB/T 31467.3-2015 (along $X$-axis $5\text{s}$, along $Y$-axis $5\text{s}$) in the horizontal direction of travel ($Y$-axis) for $2\text{h}$. | No leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Crush | 1. Test Object: Battery Pack or System. 2. Crush conditions: ① Crushing surface: $12.5\text{mm}$ diameter semi-cylinder, length $>$ width. ② Direction: $X$-axis, $Y$-axis. ③ Force: Initial $200\text{kN}$ or stop at $30\%$ deformation. ④ Observe $1\text{h}$. ⑤ Hold for $10\text{min}$. | No leakage, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. No fire or explosion (for the second set of requirements). | |
| Temperature Shock | 1. Test Object: Battery Pack or System. 2. Alternating temperature $(-40\pm2)\text{°C}$, max $30\text{min}$ duration at extremes. Keep at each extreme for $6\text{h}$, $5$ cycles. Observe $2\text{h}$ at room temp. | No leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Damp Heat Cycle | 1. Test Object: Battery Pack or System. 2. Refer to GB/T 2423.4-2018 Test $Db$ damp heat cycles. Figure 4 in GB/T 31467.3-2015 ($80\text{°C}$ max temp), $5$ cycles. Observe $2\text{h}$ at room temp. | No leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ within $30\text{min}$ after test. | |
| Seawater Immersion | 1. Test Object: Battery Pack or System. 2. Securely fastened with harness connected, immerse in $3.5\%$ NaCl solution (seawater) for $2\text{h}$ over actual transport distance. Suspend via hydraulic valve form. | No fire or explosion. | |
| External Fire | 1. Test Object: Battery Pack or System. 2. Refer to 7.10 External Fire in GB/T 31467.3-2015. | No fire or explosion. If flame occurs, must extinguish within $2\text{min}$ after fire source removal. | |
| Salt Spray | 1. Test Object: Battery Pack or System. 2. Refer to 7.11 Salt Spray in GB/T 31467.3-2015. | No leakage, outer casing rupture, fire, or explosion. | |
| High Altitude | 1. Test Object: Battery Pack or System. 2. Altitude $4000\text{m}$ or equivalent pressure, room temperature. 3. Stored for $5\text{h}$ in test environment per 7.12.2 of GB/T 31467.3-2015, then discharged at $1\text{C}$ (max $400\text{A}$) or to cut-off. Observe $2\text{h}$. | No discharge current lock, voltage surge or leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Over-temperature Protection | 1. Test Object: Battery System. 2. Refer to 7.13 Over-temperature Protection in GB/T 31467.3-2015. | BMS shall function. No gas leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Short Circuit Protection | 1. Test Object: Battery System. 2. Refer to 7.14 Short Circuit Protection in GB/T 31467.3-2015. | Protection device shall function. No leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Overcharge Protection | 1. Test Object: Battery System. 2. Refer to 7.15 Overcharge Protection in GB/T 31467.3-2015. | BMS shall function. No gas leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. | |
| Over-discharge Protection | 1. Test Object: Battery System. 2. Refer to 7.16 Over-discharge Protection in GB/T 31467.3-2015. | BMS shall function. No gas leakage, outer casing rupture, fire, or explosion. Insulation resistance $\ge 100\text{Ω}/\text{V}$ after test. |

Note: Table 6-2 mainly references GB/T 31467.3-2015, GB/T 2423.43-2008, GB/T 2423.56-2018, and GB/T 28046.1-2011.